- Detection - Measurement>
- 爱游戏ayx手机>
- Storage tank level sensor
Storage tank level sensors
{{#each product.specData:i}}{{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}{{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}
{{{product.idpText}}}
Level range: 10 m
…maintenance-free operation * Remotesensorparameter setting andlevelmonitoring via connection to the IT system Trouble-free monitoring of largetanksWith the LW2720level…
ifm electronic
Process pressure: 0 bar - 1 bar
Process temperature: -10 °C - 85 °C
Low-cost, simplelevelmeasurement Pressure compensation via internally vented cable Reduced wiring complexity due to two-wire current loop High overall accuracy and long-term stability Versions with ...
ifm electronic
Level range: 25 mm - 636 mm
…and switch-off points with window function Units with scalable analogue output and additionaloverflowalarm Clearly visible LED displayLeveland temperature monitoring with just one unit ...
ifm electronic
Level range: 0.09 m - 20 m
Process pressure: -1 bar - 25 bar
Process temperature: -40 °C - 125 °C
…, foam and slurry. Very compact capacitiveleveldetection for flexible use in a variety of applications The electrodes in thesensorform a capacitor. If the product comes into contact with thesensor, ...
UWT GmbH Level Control
Level range: 0 m - 8 m
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 60 °C
…non-contact 80 GHz FMCW radarsensorNivoRadar® NR 7100 with a narrow beam angle of 8° is used in various industrial applications instoragesilos, processtanksand IBC containers for ...
UWT GmbH Level Control
Level range: 160 mm - 4,000 mm
Process pressure: -1 bar - 16 bar
Process temperature: -40 °C - 150 °C
…handling industry as a full, demand or empty detectors for use instorageand process containers. Electronically stimulated piezos cause the probe to vibrate. As soon as thesensoris covered with ...
UWT GmbH Level Control
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
The IMP range oflevelsensorsfeature a combined transducer and controller in one self-contained unit. All IMP units from Pulsar Measurement are non-contacting, accurate, and reliablelevel…
Pulsar Measurement
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
…control systems to drive a display. IMP non-contactinglevelsensorsare suitable fortanklevelmeasurement, water and wastewater applications, stock control,tank…
Pulsar Measurement
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
…non-contacting ultrasonicsensoris designed to be used wherever you need an accurate and reliablelevelmeasurement. Its digital echo processing means the IMP+ is perfect for slurries, liquids, or anywhere ...
Pulsar Measurement
Process pressure: 0 bar - 6 bar
Process temperature: -40 °C - 80 °C
…the submersible pressuresensoris perfectly suited for the measurement of liquidlevels, also in the outdoor area. ApplicationsLevelmeasurement invesselandstorage…
Level range: 62 in - 866 in
Process temperature: -40 °F - 221 °F
TheLevelPlus®TankSlayer® liquidleveltransmitter satisfies the demand for an accurate and robust liquid-levelsensorwith unsurpassed flexibility ...
Temposonics
Level range: 12 in - 300 in
Process temperature: -40 °F - 221 °F
TheLevel加上®RefineME®液体leveltransmitter satisfies the demand for an accurate and robust liquid-levelsensorwith unsurpassed flexibility to meet most process ...
Temposonics
Level range: 12 in - 300 in
Process temperature: -40 °F - 221 °F
TheLevelPlus® SoClean® liquidleveltransmitter satisfies the demand for an accurate and robust liquid-levelsensorwith unsurpassed flexibility to meet most process ...
Temposonics
Level range: 0 m - 120 m
Process pressure: -1 bar - 160 bar
Process temperature: -196 °C - 450 °C
…a radarsensorfor continuouslevelmeasurement of liquids and bulk solids. The small process fittings offer particular advantages for liquids in smalltanksor tight mounting spaces. ...
VEGA Grieshaber KG
Level range: 0 m - 8 m
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 60 °C
…the ideal radarsensorfor non-contactlevelmeasurement in all standard applications where a high degree of protection is required. It is particularly suitable forlevelmeasurement ...
VEGA Grieshaber KG
Level range: 0 m - 15 m
Process pressure: -1 bar - 3 bar
Process temperature: -40 °C - 80 °C
…VEGAPULS 21是理想的雷达sensorfor non-contactlevelmeasurement in standard applications in all industrial plants. It is particularly suitable forlevelmeasurement ...
VEGA Grieshaber KG
Process pressure: 100 bar
Process temperature: -40 °C - 115 °C
The BLS Trimod'BestaLevelSensoris universally suitable forleveldetection and a real alternative to the tuning fork. It works in liquids of all kind, foams, bulk goods, granulates, ...
Process temperature: -25 °C - 60 °C
…The Laserlevelis an optical distancesensor用于测量润滑油公关的数量esent in pump reservoirs. Thissensorcan have a digital output that can be set to ...
Process temperature: -25 °C - 60 °C
DROPSA Laser-LevelGauge is an optical distancesensorideal for measuring the quantity of lubricant instorageor pump reservoirs. The laser probe possesses a representative and programming ...
Level range: 0.1 m - 25 m
Process pressure: 0 bar - 20 bar
Process temperature: 1,000 °C
POINTLEVELMONITORING Microwawe barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fillleveland limit detection FEATURES & BENEFITS - Simple and uncomplicated ...
Level range: 30 mm - 8,000 mm
…adverse ambient environs. Thesensorsprovide a metering range from 30 mm to 8 m via five diverse versions equipped with varying detection ranges. Thesensorsare conducive to expanded operations ...
microsonic
Level range: 30 mm - 8,000 mm
Process pressure: 6 bar
Process temperature: -25 °C - 70 °C
For filllevelmeasurements of aggressive media and in overpressure the ultrasonic transducers of the new hps+ sensorsare now fitted out - as standard - with a PTFE film. It is sealed with a FFKM O-ring ...
microsonic
Level range: 30 mm - 8,000 mm
Process pressure: 6 bar
Process temperature: -25 °C - 70 °C
The HPS+Sensorsis suitable for use in normal pressure or overpressure. The unit provides a teflon membrane, which gives protection from any aggressive media. The device features a stainless steel housing, that ensures ...
microsonic
Level range: 0 m - 250 m
Process pressure: 0.1 bar - 25 bar
Process temperature: -10 °C - 70 °C
…can be questioned by a master – the data are transferred in binary form. Basic element is a high quality stainless steelsensorwith high requirements for exact measurement with excellent long term stability. Features - ...
BD|SENSORS GmbH
Process pressure: 0 bar - 40 bar
Process temperature: -40 °C - 125 °C
The screw-in transmitter LMP 331 has been designed for continuouslevelmeasurement and is characterized by an excellent performance and a robust construction. The modular construction allows the user the highest possible ...
BD|SENSORS GmbH
Level range: 0 m - 200 m
Process pressure: 0.04 bar - 20 bar
Process temperature: -25 °C - 125 °C
…binary form. DCL 551 has been designed for hydrostaticlevelmeasurement in sewage as well as for viscous and pasty media. Basic element is a robust and high overpressure capable capacitive ceramicsensor. Features - ...
BD|SENSORS GmbH
Level range: 30 m
Process temperature: -40 °C - 80 °C
…cable inventorylevelmeasuringsensorconsisting of a sensing weight, heavy duty stainless steel cable, distance measuring component, position detectionsensorand electronics (includes ...
Level range: 0 m - 211 m
Process pressure: 0 bar - 20 bar
Process temperature: -25 °C - 60 °C
The Model SDT Submersible HydrostaticLevelTransducer indicates thelevelof liquid by continuously measuring hydrostatic pressure via its isolated sensing element. Once thesensormeasures ...
…ADVANTAGES: - Constant and continuous indication of thelevelwith high accuracy of repeatability. - Linear index of thelevel, regardless of the shape of thetankand the distance between ...
…ADVANTAGES: - Constant and continuous indication of thelevelwith high accuracy of repeatability. - Linear indication of thelevel, regardless of the shape of thetankand the distance ...
Process temperature: -20 °C - 60 °C
Continuouslevelindicator certificate N° Tuv 12Atex109610 ElectromagneticLevelindicators with a continuous signal 4-20mA Accuracy 12 mm USE: Thelevelindicators ...
…corrosive or not, and for closed or opentanks..Levelmeasurement with a differential pressure transmitter The differential pressure transmitters are used for thelevelmeasurement ...
Level range: 330 mm - 6,000 mm
Process pressure: 3 bar
Process temperature: -40 °C - 80 °C
…ultrasonic transmitter that performs liquidlevel, volume or open channel flow measurement. HART® communications are offered with a PACTware™ PC program for remote configuration and troubleshooting. Thelevel…
Level range: 1 m
Process temperature: -20 °C - 85 °C
…prevent adhesions. Opto fillsensorswith glass or PSU tip do not require a medium adjustment and are simply added top thetank. Thesesensorsare also available as explosion-proof units ...
Level range: 40 m
Process pressure: 0 psi - 580 psi
Process temperature: -40 °C - 80 °C
Drexelbrook DR2000 Guided Wave Radar is a TDRLevelMeter for measuring distance,level, volume and mass. The modular design makes it an economical and reliable solution for common applications. The ...
AMETEK Drexelbrook
Level range: 15 m
Process pressure: 0 bar - 40 bar
Process temperature: -40 °C - 200 °C
…radarsmanufactured by AMETEK Drexelbrook. They are TDR or Time Domain Reflectometry guided wave radarlevelsensorsdesigned for high accuracy measurement of totallevel, distance or ...
AMETEK Drexelbrook
Process pressure: max 69.0 bar
Process temperature: -40 °C - 125 °C
Drexelbrook TLS, TotalTankLevelSystem, provides unparalleled accuracy fortankleveland temperature measurements. The versatillity of the many probes makes TLS ...
AMETEK Drexelbrook
Level range: 1 m - 35 m
Process pressure: 10,000 Pa - 3,500,000 Pa
Process temperature: -40 °C - 300 °C
Hygienic pressure transmitter, designed for food and pharmaceutical industry, is suitable for CIP/SIP cleaning and sterilization. Smart compact design, the wetted parts is made of high quality stainless steel 316L and integral welding, ...
Shanghai LEEG Instruments Co.,Ltd.
Level range: 1 m - 200 m
Process pressure: 0.1 bar - 20 bar
Process temperature: -10 °C - 70 °C
LMP633 Submersibleleveltransmitter is designed for dealing with the most severe demandinglevelmeasurement conditions. It is the optimal choice to satisfy all of high demandlevel…
Shanghai LEEG Instruments Co.,Ltd.
Level range: 1 m - 200 m
Process temperature: -40 °C - 70 °C
Features: Piezoresistive silicon pressuresensorSmall diameter of 16mm Excellent repeatability and long term stability Parameters: Measuring range:10kPa~2MPa Output signal:4~20mA Accuracy:0.2%F.S.,0.5%F.S. Probe ...
Shanghai LEEG Instruments Co.,Ltd.
Level range: 0.13米- 15米
Process pressure: 5 bar
Process temperature: -40 °C - 80 °C
Ultrasonicsensorswith integrated transmitter for measurement of distance,level, empty space or volumes. Suitable for harsh ambient conditions. -Sensoras independent, comfortable ...
Level range: 0.07 m - 40 m
Process pressure: 5 bar
Process temperature: -30 °C - 95 °C
…ultrasonicsensorswith integrated temperature compensation for connection to NivuMaster- Series evaluation units provide a wide variety of measuring options for liquids. Thesensorsprovide accurate ...
Process temperature: -30 °C - 85 °C
…connecting with theleveldata connector, obtain a complete measurement system. Typicalleveldata collector applications Groundwaterlevelmeasurement Landfilllevel…
Level range: 75'00"
Process pressure: 1 bar - 40 bar
Process temperature: -60 °C - 200 °C
…Applications -Levelmeasurement instoragevesselsor standpipes - Fortankmetering and intankfarms - Interface measurement (separation layers) ...
BinMaster
Level range: 10'00" ft - 100'00"
Process pressure: 1 bar - 40 bar
Process temperature: -40 °C - 392 °C
…continuously measure the distance,level, and volume of powders or solids in bins,tanks, and silos. Thissensorfeatures hazardous location approvals, a very small upper dead zone, ...
BinMaster
Process pressure: -1 bar - 25 bar
Process temperature: -40 °C - 239 °C
…Capacitance Probe: PointLevelfor Solids MCP-200 compactsensorforleveldetection in light bulk solids. Looking for a low-costsensorforlevel…
BinMaster
Level range: 0 mm - 2,000 mm
Process pressure: -1 bar - 6 bar
Process temperature: 0 °C - 100 °C
…construction, epoxy resin sealed Minimum degree of protection IP65 No moving parts in thetankConductive probes constitute a valid solution for controlling thelevelof liquid with minimum value ...
…generation detectors forlevelswitch measurement The SENSseries LB 480 can be easily installed as a radiometriclevelswitch onvesselsand chemical reactors, even where other measurement ...
Level range: 0.5 m - 500 m
Process temperature: -20 °C - 75 °C
This hydrostaticlevel探针allows liquids measurement and monitoring intanks, rivers and groundwater. Thelevelmeasurement is carried out by measuring the differential ...
…cable breakdown protection •Measured value displayed by amplifier APPLICATION: PLANTS & MACHINES | FOOD & BEVERAGES •Sensormaterial selectable according to medium Stainless steel (VA4), Teflon (PTFE), PEEK •One ...
CAPTRON
Process temperature: 0 °C - 70 °C
…PT100 temperaturesensorinsensortip Different probe configurations are available •Separate M8-conector The temperature signal is can be tapped at a seperate connector
CAPTRON
Level range: 3 m
Process temperature: 0 °C - 70 °C
…Equipped with LEDs located in the thread socket to illuminate thetankor container •Capacitiveleveldetection of the medium •Illumination of thetankup to 3000 mm deep •Sensor…
CAPTRON
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to ourPrivacy Policyfor details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining