输入:电阻式传感器、TC、电阻、电压电隔离:1500 v AC准确性:< 0.1% F.S.或< 0.5°C模式:标准和ATEX配置与PC(仅Microsoft Windows) EC类型考试证书号码:13 INERIS atex0015x (ia)交货INERIS 13 atex3006x (nA)交货IECEx合格证明:INE13.0022X (ia)交货INE13.0023X (Ex nA) ATEX / IECEx分类二1 G的前女友ia IIC T4 Ga II 3 G前任nA IIC T4 Gc II 1 D前任ia IIIC T135°C Da Tia2温度转换器,旨在将来自大型面板的信号的输入信号:•转换与RTD100温度测量,RTD1000, Ni100, Ni1000或热电偶。•转换的线性电阻变化(从水平传感器或阀门)。•电压(mV)和电阻测量。导轨mountingCertified to be installed in explosive atmosphere (see codification). Input Programmable (refer to backside) Output4/20 mA Power supply Standard model 10V ... 30 Vdc ATEX version 10V ... 28 Vdc Galvanic isolation 1500V CA Accuracy ≤ 0.1% F.S. or ≤ basis accuracy (refer to backside) according to the most important value Load resistance (Vsupply-10) / 0.0215 Ω Shorted or broken line detection: Configurable 3.5 mA to 21.5 mA (NAMUR NE43) Warm-up time5 minutes Response time < 2 s Drift Voltage supply ≤ 0.01% of the current in the loop for a variation of 0.1% of Vsupply Temperature ≤ 10% of accuracy / degreeError due to CJC1.5x basis accuracy for a cold junction at 0°C