Application Hybrid cable with digital feedback channel (DSL) for flexible installation with high mechanical stress Dimensions 4 × 2.50 + (2 × 0.24) Characteristics high endurance trailing applicable very good EMC performance flame retardant and self-extinguishing acc. to IEC 60332-1-2 halogen free acc. to IEC 60754 oil resistant acc. to DIN VDE 0282 Part 10 also available as cable assembly Conductor Power: 2,5 mm² stranded tinned copper wire acc. to IEC 60228 Cl. 6, isolation polypropylene, black, green-yellow, blue and brown Signal (DSL): 0,24 mm² stranded tinnned copper wire, isolation polyethylene, grey and pink Core Signalwires: twisted aluminised tape wrapped, braidings of tinned copper wires (covering ≥ 85 %), pair and four wires twisted in layer with fillers in gaps and central filler Shield Shield braiding of tinned copper wires, covering ≥ 85 % Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 Outer diameter 12.0 mm (0.472 in) Nominal voltage 0.6 / 1 kV for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Test voltage 4 kV 50Hz AC Minimum bending radius allowed 5 × outer diameter (single), 12 × outer diameter (repeated) Maximum acceleration 50 m/s² (164 ft/s²) Process velocity 300 m/min (984 ft/min) Bendings 10.000.000 at ≥ 12 × outer diameter Torsion ≤± 30° on 1 meter (3.28 feet) Horizontal length max. 50 m (max. 164 ft) Temperature range – 40 °C to + 80 °C (-40 °F to +176 °F) fixed installation, – 20 °C to + 60 °C (- 4 °F to + 140 °F) repeated Number of wires 6 Order-No. L45467-Y516-W8